JOURNAL DESCRIPTION

The Medical Radiology and Radiation Safety journal ISSN 1024-6177 was founded in January 1956 (before December 30, 1993 it was entitled Medical Radiology, ISSN 0025-8334). In 2018, the journal received Online ISSN: 2618-9615 and was registered as an electronic online publication in Roskomnadzor on March 29, 2018. It publishes original research articles which cover questions of radiobiology, radiation medicine, radiation safety, radiation therapy, nuclear medicine and scientific reviews. In general the journal has more than 30 headings and it is of interest for specialists working in thefields of medicine¸ radiation biology, epidemiology, medical physics and technology. Since July 01, 2008 the journal has been published by State Research Center - Burnasyan Federal Medical Biophysical Center of Federal Medical Biological Agency. The founder from 1956 to the present time is the Ministry of Health of the Russian Federation, and from 2008 to the present time is the Federal Medical Biological Agency.

Members of the editorial board are scientists specializing in the field of radiation biology and medicine, radiation protection, radiation epidemiology, radiation oncology, radiation diagnostics and therapy, nuclear medicine and medical physics. The editorial board consists of academicians (members of the Russian Academy of Science (RAS)), the full member of Academy of Medical Sciences of the Republic of Armenia, corresponding members of the RAS, Doctors of Medicine, professor, candidates and doctors of biological, physical mathematics and engineering sciences. The editorial board is constantly replenished by experts who work in the CIS and foreign countries.

Six issues of the journal are published per year, the volume is 13.5 conventional printed sheets, 88 printer’s sheets, 1.000 copies. The journal has an identical full-text electronic version, which, simultaneously with the printed version and color drawings, is posted on the sites of the Scientific Electronic Library (SEL) and the journal's website. The journal is distributed through the Rospechat Agency under the contract № 7407 of June 16, 2006, through individual buyers and commercial structures. The publication of articles is free.

The journal is included in the List of Russian Reviewed Scientific Journals of the Higher Attestation Commission. Since 2008 the journal has been available on the Internet and indexed in the RISC database which is placed on Web of Science. Since February 2nd, 2018, the journal "Medical Radiology and Radiation Safety" has been indexed in the SCOPUS abstract and citation database.

Brief electronic versions of the Journal have been publicly available since 2005 on the website of the Medical Radiology and Radiation Safety Journal: http://www.medradiol.ru. Since 2011, all issues of the journal as a whole are publicly available, and since 2016 - full-text versions of scientific articles. Since 2005, subscribers can purchase full versions of other articles of any issue only through the National Electronic Library. The editor of the Medical Radiology and Radiation Safety Journal in accordance with the National Electronic Library agreement has been providing the Library with all its production since 2005 until now.

The main working language of the journal is Russian, an additional language is English, which is used to write titles of articles, information about authors, annotations, key words, a list of literature.

Since 2017 the journal Medical Radiology and Radiation Safety has switched to digital identification of publications, assigning to each article the identifier of the digital object (DOI), which greatly accelerated the search for the location of the article on the Internet. In future it is planned to publish the English-language version of the journal Medical Radiology and Radiation Safety for its development. In order to obtain information about the publication activity of the journal in March 2015, a counter of readers' references to the materials posted on the site from 2005 to the present which is placed on the journal's website. During 2015 - 2016 years on average there were no more than 100-170 handlings per day. Publication of a number of articles, as well as electronic versions of profile monographs and collections in the public domain, dramatically increased the number of handlings to the journal's website to 500 - 800 per day, and the total number of visits to the site at the end of 2017 was more than 230.000.

The two-year impact factor of RISC, according to data for 2017, was 0.439, taking into account citation from all sources - 0.570, and the five-year impact factor of RISC - 0.352.

Medical Radiology and Radiation Safety. 2019. Vol. 64. No. 3. P. 5–10

DOI: 10.12737/article_5cf23053d04654.51745769

A.V. Belousov1,2, R.B. Bahtiosin2, M.A. Kolyvanova1, G.A. Krusanov1,3, L.I. Shulepova4, V.N. Morozov1

Calculation of the Depth Dependence of Relative Biological Effectiveness for Clinical Proton Beams

1. A.I. Burnasyan Federal Medical Biophysical Center, Moscow, Russia. E-mail: This email address is being protected from spambots. You need JavaScript enabled to view it. ;
2. Faculty of Physics, M.V. Lomonosov Moscow State University, Moscow, Russia;
3. D.V. Skobeltsyn Institute of Nuclear Physics, M.V. Lomonosov Moscow State University, Moscow, Russia;
4. Federal High-Tech Center for Medical Radiology of Federal Medical Biological Agency, Dimitrovgrad, Russia

A.V. Belousov – Assoc. Prof., PhD Phys.-Math.;
R.B. Bahtiosin – Student;
M.A. Kolyvanova – Head of Lab.;
G.A. Krusanov – Research Fellow;
L.I. Shulepova – Director General; V.N. Morozov – Research Fellow

Abstract

Purpose: Accurate establishing the value of relative biological effectiveness (RBE) for high energy protons is one of the main challenges of modern radiotherapy. The purpose of the study is to calculate the depth dependence of RBE for proton beams forming a spread-out Bragg peak.

Material and methods: Spatial distributions of absorbed dose and dose-average linear energy transfer (LET) for 50-100 MeV (0.5 MeV energy step) monochromatic proton beams were obtained by Monte-Carlo computer simulation using Geant4 software. A linear dependence of RBE on the dose-average LET was used. Absorbed dose distributions were obtained in a water phantom for monochromatic pencil proton beams of 2.5 mm radius. The absorbed dose and the dose-average LET values were calculated in voxels with dimensions of 2×2×0.2 mm.

Results: Calculations of depth dependencies of absorbed dose and dose-average LET for 50–100 MeV monochromatic proton beams were performed. Depth dependencies of RBE for these beams were established. The weighing coefficients values allowing to generate uniformspread-out Bragg peak (SOBP) were determined. Depth distribution of RBE-weighted dose and RBE values for SOBP were found.

Conclusion: The impact of the initial beam energy step on the degree of homogeneity of the modified Bragg curve was investigated. It was shown that a step up to 1.5 MeV is acceptable for generate a smooth Bragg curve. The depth dependence of the average RBE value is a complex function, which rapidly changes especially at the far end of the SOBP. RBE may vary up to 10–30 % compared to current clinical value. The linear model of RBE–LET dependence shown in the study can be easily used in dosimetric planning systems, that may will significantly improve the quality of proton radiotherapy.

Key words: proton radiotherapy, relative biological effectiveness, linear energy transfer, spread-out Bragg peak, Monte-Carlo method, Geant4

REFERENCES

1. Amaldi U. Future trends in cancer therapy with particle accelerators. Med Phys. 2004;14(1):7-16. DOI: 10.1078/0939-3889-00193.

2. Klimanov VA, Galjautdinova JJ, Zabelin MV. Proton radiotherapy: current status and future prospects. Med Fizika. 2017;2(74):89-121. (Russian).

3. Scholz M. Heavy ion tumour therapy. Nucl Instrum Methods Phys Res B. 2000;161-163:76-82. DOI: 10.1016/S0168-583X(99)00669-2.

4. Paganetti H, Niemierko A, Ancukiewicz M, Gerweck LE, Goitein M, Loeffler JS, Suit HD. Relative biological effectiveness (RBE) values for proton beam therapy. Int J Radiat Oncol Biol Phys. 2002;53(2):407-21. DOI: 10.1016/S0360-3016(02)02754-2.

5. Goodhead DT. Energy deposition stochastics and track structure: what about the target? Radiat Prot Dosimetry. 2006;122(1-4):3-15. DOI: 10.1093/rpd/ncl498.

6. Krämer M, Weyrather WK, Scholz M. The increased biological effectiveness of heavy charged particles: from radiobiology to treatment planning. Technol Cancer Res Treat. 2003;2(5):427-36. DOI: 10.1177/153303460300200507.

7. Paganetti H. Relative biological effectiveness (RBE) values for proton beam therapy. Variations as a function of biological endpoint, dose, and linear energy transfer. Phys Med Biol. 2014;59(22):R419-72. DOI: 10.1088/0031-9155/59/22/R419.

8. Paganetti H, Giantsoudi D. Relative biological effectiveness uncertainties and implications for beam arrangements and dose constraints in proton therapy. Semin Radiat Oncol. 2018;28(3):256-63. DOI: 10.1016/j.semradonc.2018.02.010.

9. Lühr A, von Neubeck C, Krause M, Troost EGC. Relative biological effectiveness in proton beam therapy – Current knowledge and future challenges. Clin Transl Radiat Oncol. 2018;9:35-41. DOI: 10.1016/j.ctro.2018.01.006.

10. Wouters BG, Skarsgard LD, Gerweck LE, Carabe-Fernandez A, Wong M, Durand RE, et al. Radiobiological intercomparison of the 160 MeV and 230 MeV proton therapy beams at the Harvard Cyclotron Laboratory and at Massachusetts General Hospital. Radiat Res. 2015;183(2):174-87. DOI: 10.1667/RR13795.1.

11. Wedenberg M, Toma-Dasu I. Disregarding RBE variation in treatment plan comparison may lead to bias in favor of proton plans. Med Phys. 2014;41(9):091706. DOI: 10.1118/1.4892930.

12. Paganetti H. Relating proton treatments to photon treatments via the relative biological effectiveness should we revise current clinical practice? Int J Radiat Oncol Biol Phys. 2015;91(5):892-4. DOI: 10.1016/j.ijrobp.2014.11.021.

13. Cortes-Giraldo MA, Carabe AA. Critical study of different Monte Carlo scoring methods of dose average linear-energy-transfer maps calculated in voxelized geometries irradiated with clinical proton beams. Phys Med Biol. 2015;60(7):2645-69. DOI: 10.1088/0031-9155/60/7/2645.

14. Granville DA, Sawakuchi GO. Comparison of linear energy transfer scoring techniques in Monte Carlo simulations of proton beams. Phys Med Biol. 2015;60(14):N283-91. DOI: 10.1088/0031-9155/60/14/N283.

15. Hawkins RB. A microdosimetric-kinetic theory of the dependence of the RBE for cell death on LET. Med Phys. 1998;25(7. Pt 1):1157-70. DOI: 10.1118/1.598307.

16. Wilkens JJ, Oelfke U. A phenomenological model for the relative biological effectiveness in therapeutic proton beams. Phys Med Biol. 2004;49(13):2811-25. DOI: 10.1088/0031-9155/49/13/004.

17. Grassberger C, Trofimov A, Lomax A, Paganetti H. Variations in linear energy transfer within clinical proton therapy fields and the potential for biological treatment planning. Int J Radiat Oncol Biol Phys. 2011;80(5):1559-66. DOI: 10.1016/j.ijrobp.2010.10.027.

18. Wedenberg M, Lind BK, Hårdemark B. A model for the relative biological effectiveness of protons: the tissue specific parameter α/β of photons is a predictor for the sensitivity to LET changes. Acta Oncol. 2013 Apr;52(3):580-8. DOI: 10.3109/0284186X.2012.705892.

19. Belousov AV, Krusanov GA, Chernyaev AP. Calculation of the proton biological efficiency in thin layer of biological tissues. Med Fizika. 2018;2(78):5-11. (Russian).

20. Allison J, Amako K, Apostolakis J, Arce P, Asai M, Aso T, et al. Recent developments in Geant4. Nucl Instrum Methods Phys Res A. 2016;835:186-225. DOI: 10.1016/j.nima.2016.06.125.

21. Sadovnichy VA, Tikhonravov AV, Voevodin VV, Opanasenko VY. “Lomonosov”: supercomputing at Moscow State University. In contemporary high-performance computing: from petascale toward exascale. Boca Raton: CRC Press; 2013.

22. Jette D, Chen W. Creating a spread-out Bragg peak in proton beams. Phys Med Biol. 2011;56(11):N131-8. DOI: 10.1088/0031-9155/56/11/N01.

For citation: Belousov AV, Bahtiosin RB, Kolyvanova MA, Krusanov GA, Shulepova LI, Morozov VN. Calculation of the Depth Dependence of Relative Biological Effectiveness for Clinical Proton Beams. Medical Radiology and Radiation Safety. 2019;64(3):5-10. (Russian).

DOI: 10.12737/article_5cf23053d04654.51745769

PDF (RUS) Full-text article (in Russian)

PDF (ENG) Full-text article (in English)

Contact Information

 

46, Zhivopisnaya st., 123098, Moscow, Russia Phone: +7 (499) 190-95-51. E-mail: This email address is being protected from spambots. You need JavaScript enabled to view it.

Journal location

Attendance

2950232
Today
Yesterday
This week
Last week
This month
Last month
For all time
1072
3041
7075
20395
48528
113593
2950232

Forecast today
7128


Your IP:216.73.216.48