Medical Radiology and Radiation Safety. 2018. Vol. 63. No. 6. P. 65 –70

RADIATION PHYSICS, TECHNOLOGY AND DOSIMETRY

DOI: 10.12737/article_5c0e7486915d55.10064971

A.O. Lisovskaya1,2, A.A. Loginova1, K.A. Galich2, V.N. Belyaev2, A.V. Nechesnyuk1

Evaluation of the Dose Index Using Cone-Beam Computed Tomography for Pediatric Patients

1. Dmitry Rogachev National Research Center of Pediatric Hematology, Oncology and Immunology, Moscow, Russia. E-mail: This email address is being protected from spambots. You need JavaScript enabled to view it. ;
2. National Research Nuclear University MEPhI, Moscow, Russia

A.O. Lisovskaya – Medical Physicist, Post-Graduate Student; A.A. Loginova – Senior Medical Physicist, PhD Applicant;
K.A. Galich – Student; V.N. Belyaev – Dr. Sci. Phys.-Math., Prof.; A.V. Nechesnyuk – Head of Dep., PhD Med.

Abstract

Purpose: Cone-beam computed tomography (CBCT) is an indispensable procedure for accurate patient positioning during radiation therapy (RT) in many clinical cases. However, the patients get an additional dose using CBCT. This dose is neither therapeutic nor diagnostic. It is very difficult to obtain the reliable information about the dose distribution within the patient using the CBCT. Despite this, there is a need to control the additional dose for the pediatric patients and reduce it. There are different approaches of imaging dose evaluation. Most accurate methods are based on the Monte-Carlo calculation and thermoluminescent dosimeters-based measurements. However, the implementation of these methods is complex and cumbersome, that makes impossible their application in routine clinical practice. The evaluation of dose indexes is an accessible and convenient alternative. The purpose of this study is evaluation of the cone beam computed tomography dose indexes for different imaging protocols and object sizes.

Material and methods: The technique based on absolute and relative dose measurements for CBCT was used in this study. Absolute dose measurements were performed at the periphery and center of the FREEPOINT (CIRS) phantom using the Farmer type chamber FC65-P for each CBCT protocols. FREEPOINT (20 cm height, 30 cm width, 30 cm length) was used for imitation big chest and pelvis. Inner insert (16 cm diameter) of the phantom was used for imitation head, small chest and pelvis. The dose profiles were measured using I’mRT MatriXX (IBA) and analyzed by OmniPro-I’mRT software, dose indexes DLP (dose–length product) were calculated.

Results: The dose indexes were identified for five protocols corresponding three scanning areas (Head and Neck, Chest and Pelvis). The dose indexes were 51.82 and 90.25 mGy×cm using Head and Neck S20 and Head and Neck M20 protocols respectively. The lowest dose index was obtained 13.28 mGy×cm for Fast Head and Neck S20.
It was established that the scanning object size strongly affects on the dose index values and, as result, on the absorbed dose within the patient. The dose indexes were 305.42 and 187.53 mGy×cm using scanning protocol Chest M20 for small and big phantoms respectively. The similar results were obtained for scanning protocol Pelvis M15. The highest dose index was obtained 846.93 mGy×cm for the small phantom, while the dose index was 563.79 mGy×cm for the big phantom.
The necessity of several clinical protocols to scan different areas was shown. Using of the Pelvis M15 protocol for head scanning may increase the additional point dose 96 times in comparison with Fast Head and Neck S20 protocol.

Conclusion: The dose indexes were evaluated taking into account the size of the scanning object for different imaging protocols. Routine use of CBCT in clinical practice requires a sensible choice of the scanning protocol based on the results of the dose index estimation.

Key words: IGRT, CTCB, dose index, scanning protocols, visualization dose

REFERENCE

  1. Islam M, Purdie T, Norrlinger B, et al. Patient dose from kilovoltage cone beam computed tomography imaging in radiation therapy. Med Phys. 2006;33:1573-82. DOI: 10.1118/1.2198169.
  2. Khoruzhik SA, Mikhailov AN. Radiation dose during computed tomographic studies: dosimetric parameters, measurement, modes of reduction, radiation risk. J Radiol Nucl Med. 2007;6:53-63. (Russian).
  3. Alaei P, Spezi E. Imaging dose from cone beam computed tomography in radiation therapy. Physica Medica. 2015;31(7):647-58. DOI: 10.1016/j.ejmp.2015.06.003.
  4. Ding G, Munro P, Pawlowski J, et al. Reducing radiation exposure to patients from kV-CBCT imaging. Radiotherapy and Oncology. 2010;97(3):585-92. DOI: 10.1016/j.radonc.2010.08.005.
  5. Brenner D. Induced second cancers after prostate-cancer radiotherapy: no cause for concern. Int. J. Radiat. Oncol. Biol. Phys. 2006;65:637-39. DOI: 10.1016/j.radonc.2010.08.005.
  6. Murphy MJ, Balter J, BenComo J et al. The management of imaging dose during image-guided radiotherapy: Report of AAPM Task Group 75. Med Phys. 2007;34:4041-63. DOI: 10.1118/1.2775667.
  7. Kalender WA. Computer Tomography: Fundamentals, System Technology, Image Quality, Applications. Moscow: Technosphera. 2006. 344 p. (Russian).
  8. Marks L, Yorke E, Jackson A, et al. Use of normal tissue complication probability models in the clinic. Int. J. Radiat. Oncol. Biol. Phys. 2010;76(3):10–19. Doi: 10.1016/j.ijrobp.2009.07.1754.
  9. Marchant T, Joshi K. Comprehensive Monte-Carlo study of patient doses from cone-beam CT imaging in radiotherapy. J Radiol Prot. 2017;37(1):13-30. DOI: 10.1088/1361-6498/37/1/13.
  10. Groves A, Owen K, Courtney H, et al. 16-detector multislice CT: dosimetry estimation by TLD measurement compared with Monte-Carlo simulation. BJR. 2004;77:662–65. DOI: 10.1259/bjr/48307881.
  11. Amer А, Marchant Т, Sykes JR, et al. Imaging doses from the Elekta Synergy X-ray cone beam CT system. BJR. 2007;80:476–82. DOI: 10.1259/bjr/80446730.
  12. Buckley J, Wilkinson D, Malaroda A, Metcalf P. Investigation of the radiation dose from cone beam CT for image guided radiotherapy: a comparison of methodologies. J. Appl. Clin. Med. Phys. 2018;19(1):174-83. DOI: 10.1002/acm2.12239.
  13. Chair CM, Coffey C, DeWerd L, et al. AAPM protocol for 40–300 kV X-ray beam dosimetry in radiotherapy and radiobiology. Med Phys. 2001;28(6):868-93. DOI: 10.1118/1.1374247.
  14. Dixon R, Anderson A, Bakalyar D, et al. Comprehensive Methodology for the Evaluation of Radiation Dose in X-Ray Computed Tomography. Report of AAPM Task Group. 2010;111: 20740–3846.
  15. Scandurra D, Lawford C. A dosimetry technique for measuring kilovoltage cone-beam CT dose on a linear accelerator using radiotherapy equipment. J. Appl. Clin. Med. Phys. 2014;15(4):80-91. DOI: 10.1120/jacmp.v15i4.4658.
  16. Liao X, Wang Y, Lang J, et al. Variation of patient imaging doses with scanning parameters for linac-integrated kilovoltage cone beam CT. Bio-Med. Mater. Engin. 2015;26:1659-67. DOI: 10.3233/BME-151465.
  17. Song W, Kamath S, Ozawaet. S, et al. A dose comparison study between XVI and OBI CBCT systems. Med Phys. 2008;35(2):480-6. DOI: 10.1118/1.2825619.
  18. Ding G, Alaei P, Curran B, et al. Image Guidance Doses to Radiotherapy Patients. Med Phys. 2018;45(5):84-99. DOI: 10.1002/mp.12824.
  19. Golikov VY, Kalnitsky SA, Sarychev SS, Bratilova AA. Guidelines. 2.6.1.2944-11. Ionizing radiation, radiation safety. Control of effective radiation doses of patients during medical X-ray examinations. 2011. (Russian).

For citation: Lisovskaya AO, Loginova AA, Galich KA, Belyaev VN, Nechesnyuk AV. Evaluation of the Dose Index Using Cone-Beam Computed Tomography for Pediatric Patients. Medical Radiology and Radiation Safety. 2018;63(6):65-70. (Russian).

DOI: 10.12737/article_5c0e7486915d55.10064971

PDF (RUS) Full-text article (in Russian)