JOURNAL DESCRIPTION

The Medical Radiology and Radiation Safety journal ISSN 1024-6177 was founded in January 1956 (before December 30, 1993 it was entitled Medical Radiology, ISSN 0025-8334). In 2018, the journal received Online ISSN: 2618-9615 and was registered as an electronic online publication in Roskomnadzor on March 29, 2018. It publishes original research articles which cover questions of radiobiology, radiation medicine, radiation safety, radiation therapy, nuclear medicine and scientific reviews. In general the journal has more than 30 headings and it is of interest for specialists working in thefields of medicine¸ radiation biology, epidemiology, medical physics and technology. Since July 01, 2008 the journal has been published by State Research Center - Burnasyan Federal Medical Biophysical Center of Federal Medical Biological Agency. The founder from 1956 to the present time is the Ministry of Health of the Russian Federation, and from 2008 to the present time is the Federal Medical Biological Agency.

Members of the editorial board are scientists specializing in the field of radiation biology and medicine, radiation protection, radiation epidemiology, radiation oncology, radiation diagnostics and therapy, nuclear medicine and medical physics. The editorial board consists of academicians (members of the Russian Academy of Science (RAS)), the full member of Academy of Medical Sciences of the Republic of Armenia, corresponding members of the RAS, Doctors of Medicine, professor, candidates and doctors of biological, physical mathematics and engineering sciences. The editorial board is constantly replenished by experts who work in the CIS and foreign countries.

Six issues of the journal are published per year, the volume is 13.5 conventional printed sheets, 88 printer’s sheets, 1.000 copies. The journal has an identical full-text electronic version, which, simultaneously with the printed version and color drawings, is posted on the sites of the Scientific Electronic Library (SEL) and the journal's website. The journal is distributed through the Rospechat Agency under the contract № 7407 of June 16, 2006, through individual buyers and commercial structures. The publication of articles is free.

The journal is included in the List of Russian Reviewed Scientific Journals of the Higher Attestation Commission. Since 2008 the journal has been available on the Internet and indexed in the RISC database which is placed on Web of Science. Since February 2nd, 2018, the journal "Medical Radiology and Radiation Safety" has been indexed in the SCOPUS abstract and citation database.

Brief electronic versions of the Journal have been publicly available since 2005 on the website of the Medical Radiology and Radiation Safety Journal: http://www.medradiol.ru. Since 2011, all issues of the journal as a whole are publicly available, and since 2016 - full-text versions of scientific articles. Since 2005, subscribers can purchase full versions of other articles of any issue only through the National Electronic Library. The editor of the Medical Radiology and Radiation Safety Journal in accordance with the National Electronic Library agreement has been providing the Library with all its production since 2005 until now.

The main working language of the journal is Russian, an additional language is English, which is used to write titles of articles, information about authors, annotations, key words, a list of literature.

Since 2017 the journal Medical Radiology and Radiation Safety has switched to digital identification of publications, assigning to each article the identifier of the digital object (DOI), which greatly accelerated the search for the location of the article on the Internet. In future it is planned to publish the English-language version of the journal Medical Radiology and Radiation Safety for its development. In order to obtain information about the publication activity of the journal in March 2015, a counter of readers' references to the materials posted on the site from 2005 to the present which is placed on the journal's website. During 2015 - 2016 years on average there were no more than 100-170 handlings per day. Publication of a number of articles, as well as electronic versions of profile monographs and collections in the public domain, dramatically increased the number of handlings to the journal's website to 500 - 800 per day, and the total number of visits to the site at the end of 2017 was more than 230.000.

The two-year impact factor of RISC, according to data for 2017, was 0.439, taking into account citation from all sources - 0.570, and the five-year impact factor of RISC - 0.352.

Medical Radiology and Radiation Safety. 2022. Vol. 67. № 5

DOI: 10.33266/1024-6177-2022-67-5-69-74

K.S. Anpilogova1, V.M. Puchnin2, G.E. Trufanov1, A.Yu. Efimtsev1,
V.A. Fokin1, A.V. Shchelokova2, A.E. Andreichenko2,3,
T.M. Bobrovskaya3

INVESTIGATION OF THE DIAGNOSTIC QUALITY OF BREAST MRI USING INNOVATIVE WIRELESS COILS

1 V.A. Almazov National Medical Research Centre, St. Petersburg, Russia

2 National Research University ITMO, Faculty of Physics and Technology, St. Petersburg, Russia

3 Scientific and Practical Clinical Center for Diagnostics and Telemedicine Technologies of the Department of Health of Moscow, Russia

Contact person: Anpilogova K.S.: email: This email address is being protected from spambots. You need JavaScript enabled to view it.


ABSTRACT

Purpose Determination of the diagnostic capabilities of metadevices for breast MR examination in women.

Material and methods In the study, two types of metadevices for examining the mammary glands were considered – for imaging in a field with magnetic induction of 3 T and 1.5 T. 11 healthy women of reproductive age were examined, magnetic resonance images of T1 (turbo spin echo) and T1 3D gradient echo (GRE) were obtained based on the Dixon method with fat saturation. The images were evaluated by radiologists on a 5-point Likert scale.

Results The images obtained using the metadevices were characterized by acceptable and comparable absolute and relative signal-to-noise ratios comparing them to images obtained using a standard coil at the same spatial resolution and with a decrease in input power by an average of 27 times for 3.0 T. At the same time, for 1.5 T, the input power was reduced by a factor of 15.6, and the signal-to-noise ratio was increased by a factor of 2. For image quality criteria in terms of presence/absence of artifacts, the average score for the metadevice was higher than the score for the specialized coil by 3 T. For 1.5 T, this parameter turned out to be the same, which was probably associated with a lower level of artifacts by 1.5 T than by 3 T in general.

Discussion Analysis of the collected assessments of independent experts indicates that the diagnostic characteristics of magnetic resonance images of the mammary glands obtained using ceramic-based (for 3 T) and wire-based (for 1.5 T) metadevices are of a good and average level, and are comparable in terms of all criteria with standard approaches.

Conclusions The assessment of the quality of the obtained images demonstrates the acceptable quality of imaging and reflects the possibility of their application in clinical practice, taking into account ongoing improvements and optimization of the entire set of pulse sequences for MRI of the mammary glands.

Keywords: magnetic resonance imaging, MR mammography, metadevice, image quality

For citation: Anpilogova KS, Puchnin VM, Trufanov GE, Efimtsev AYu, Fokin VA, Shchelokova AV, Andreichenko AE, Bobrovskaya TM. Investigation of the Diagnostic Quality of Breast MRI Using Innovative Wireless Coils. Medical Radiology and Radiation Safety. 2022;67(5):69-74. DOI: 10.33266/1024-6177-2022-67-5-69-74


References

1. Ageyeva L.I., Aleksandrova G.A., Zaychenko N.M., et.al. Zdravookhraneniye v Rossii. 2019 = Health Care in Russia. 2019. Moscow Publ., 2019. 170 p. (In Russ.).

2. Zakharova N.A., Semiglazov V.F., Duffy S.W. Skrining Raka Molochnoy Zhelezy: Problemy i Resheniya = Breast Cancer Screening: Problems and Solutions. Moscow, GEOTAR-Media Publ., 2011. 176 p. (In Russ.).

3. Serebryakova S.V., Trufanov G.Ye., Yukhno Ye.A. Magnetic Resonance Semiotics of Breast Cancer. Opukholi Zhenskoy Reproduktivnoy Sistemy = Tumors of Female Reproductive System. 2009;3-4:20-25 (In Russ.).

4. Bakker M.F., de Lange S.V., Pijnappel R.M., et al. Supplemental MRI Screening for Women with Extremely Dense Breast Tissue. New England Journal of Medicine. 2019;381;22:2091-2102.

5. Aleksandrova L.M., Kalinina A.M., Ipatov P.V., et al. Detection of Breast Cancer: State of the Problem, Solutions. Onkologiya. Zhurnal im. P.A. Gertsena = P.A. Herzen Journal of Oncology. 2016;5;2:34-39 (In Russ.).

6. Gao Y., Reig B., Heacock L., et al. Magnetic Resonance Imaging in Screening of Breast Cancer. Radiologic Clinics. 2021;59;1:85-98. DOI: 10.1016/j.rcl.2020.09.004.

7. Chiarelli A.M., Blackmore K.M., Muradali D., et al. Performance Measures of Magnetic Resonance Imaging Plus Mammography in the High Risk Ontario Breast Screening Program. Journal of the National Cancer Institute. 2020;112;2:136-144.

8. Onishi N., Sadinski M., Hughes M.C., et al. Ultrafast Dynamic Contrast-Enhanced Breast MRI May Generate Prognostic Imaging Markers of Breast Cancer. Breast Cancer Research. 2020;22;1:1-13. DOI: 10.1186/s13058-020-01292-9.

9. Saadatmand S., Geuzinge H.A., Rutgers E.J., et al. MRI Versus Mammography for Breast Cancer Screening in Women with Familial Risk (FaMRIsc): a Multicentre, Randomised, Controlled Trial. The Lancet Oncology. 2019;20;8:1136-1147. DOI: 10.1016/S1470-2045(19)30275-X. 

10. Strigel R.M., Rollenhagen J., Burnside E.S., et al. Screening Breast MRI Outcomes in Routine Clinical Practice: Comparison to BI-RADS Benchmarks. Academic Radiology. 2017;24;4:411-417.

11. Lehman C.D., Lee J.M., DeMartini W.B., et al. Screening MRI in Women with a Personal History of Breast Cance. Journal of the National Cancer Institute. 2016;108;3:djv349.

12. Clauser P., Dietzel M., Weber M., et al. Motion Artifacts, Lesion Type, and Parenchymal Enhancement in Breast MRI: what Does Really Influence Diagnostic Accuracy? Acta Radiologica. 2019;60;1:19-27. DOI: 10.1177/0284185118770918.

13. Shchelokova A., Ivanov V., Mikhailovskaya A., et al. Ceramic Resonators for Targeted Clinical Magnetic Resonance Imaging of the Breast. Nature Communications. 2020;11;1:1-7.

14. Ivanov V., Shchelokova A., Andreychenko A., Slobozhanyuk A. Coupled Very-High Permittivity Dielectric Resonators for Clinical MRI. Applied Physics Letters. 2020;117;10:103701. 

15. Puchnin V., Solomakha G., Nikulin A., et al. Metamaterial Inspired Wireless Coil for Clinical Breast Imaging. Journal of Magnetic Resonance. 2021;322:106877.

16. Bickelhaupt S., Laun F.B., Tesdorff J., et al. Fast and Noninvasive Characterization of Suspicious Lesions Detected at Breast Cancer X-Ray Screening: Capability of Diffusion-Weighted MR Imaging with MIPs. Radiology. 2016;278;3:689-697.

17. Zhang S., Seiler S., Wang X., et al. CEST-Dixon for Human Breast Cancer Characterization at 3T: a Preliminary Study. Magnetic Resonance in Medicine. 2018;80;3:895-903.

18. Sánchez-González J., Luna A. Diffusion MRI Outside the Brain: A Case-Based Review and Clinical Applications / Eds Luna A., Ribes R., Soto J.A. Springer Science & Business Media, 2011. P. 51–72.

19. Vinogradov E., Sherry A.D., Lenkinski R.E. CEST: from Basic Principles to Applications, Challenges and Opportunities. Journal of Magnetic Resonance. 2013;229:155-172.

 

 PDF (RUS) Full-text article (in Russian)

Conflict of interest. The authors declare no conflict of interest.

Financing. The Russian Science Foundation (Project No. 18-75-1008).

Contribution. Article was prepared with equal participation of the authors.

Article received: 17.04.2022.  Accepted for publication: 06.05.2022

 

 

Contact Information

 

46, Zhivopisnaya st., 123098, Moscow, Russia Phone: +7 (499) 190-95-51. E-mail: This email address is being protected from spambots. You need JavaScript enabled to view it.

Journal location

Attendance

2766703
Today
Yesterday
This week
Last week
This month
Last month
For all time
2597
4471
25087
18409
74446
75709
2766703

Forecast today
3024


Your IP:216.73.216.210