JOURNAL DESCRIPTION

The Medical Radiology and Radiation Safety journal ISSN 1024-6177 was founded in January 1956 (before December 30, 1993 it was entitled Medical Radiology, ISSN 0025-8334). In 2018, the journal received Online ISSN: 2618-9615 and was registered as an electronic online publication in Roskomnadzor on March 29, 2018. It publishes original research articles which cover questions of radiobiology, radiation medicine, radiation safety, radiation therapy, nuclear medicine and scientific reviews. In general the journal has more than 30 headings and it is of interest for specialists working in thefields of medicine¸ radiation biology, epidemiology, medical physics and technology. Since July 01, 2008 the journal has been published by State Research Center - Burnasyan Federal Medical Biophysical Center of Federal Medical Biological Agency. The founder from 1956 to the present time is the Ministry of Health of the Russian Federation, and from 2008 to the present time is the Federal Medical Biological Agency.

Members of the editorial board are scientists specializing in the field of radiation biology and medicine, radiation protection, radiation epidemiology, radiation oncology, radiation diagnostics and therapy, nuclear medicine and medical physics. The editorial board consists of academicians (members of the Russian Academy of Science (RAS)), the full member of Academy of Medical Sciences of the Republic of Armenia, corresponding members of the RAS, Doctors of Medicine, professor, candidates and doctors of biological, physical mathematics and engineering sciences. The editorial board is constantly replenished by experts who work in the CIS and foreign countries.

Six issues of the journal are published per year, the volume is 13.5 conventional printed sheets, 88 printer’s sheets, 1.000 copies. The journal has an identical full-text electronic version, which, simultaneously with the printed version and color drawings, is posted on the sites of the Scientific Electronic Library (SEL) and the journal's website. The journal is distributed through the Rospechat Agency under the contract № 7407 of June 16, 2006, through individual buyers and commercial structures. The publication of articles is free.

The journal is included in the List of Russian Reviewed Scientific Journals of the Higher Attestation Commission. Since 2008 the journal has been available on the Internet and indexed in the RISC database which is placed on Web of Science. Since February 2nd, 2018, the journal "Medical Radiology and Radiation Safety" has been indexed in the SCOPUS abstract and citation database.

Brief electronic versions of the Journal have been publicly available since 2005 on the website of the Medical Radiology and Radiation Safety Journal: http://www.medradiol.ru. Since 2011, all issues of the journal as a whole are publicly available, and since 2016 - full-text versions of scientific articles. Since 2005, subscribers can purchase full versions of other articles of any issue only through the National Electronic Library. The editor of the Medical Radiology and Radiation Safety Journal in accordance with the National Electronic Library agreement has been providing the Library with all its production since 2005 until now.

The main working language of the journal is Russian, an additional language is English, which is used to write titles of articles, information about authors, annotations, key words, a list of literature.

Since 2017 the journal Medical Radiology and Radiation Safety has switched to digital identification of publications, assigning to each article the identifier of the digital object (DOI), which greatly accelerated the search for the location of the article on the Internet. In future it is planned to publish the English-language version of the journal Medical Radiology and Radiation Safety for its development. In order to obtain information about the publication activity of the journal in March 2015, a counter of readers' references to the materials posted on the site from 2005 to the present which is placed on the journal's website. During 2015 - 2016 years on average there were no more than 100-170 handlings per day. Publication of a number of articles, as well as electronic versions of profile monographs and collections in the public domain, dramatically increased the number of handlings to the journal's website to 500 - 800 per day, and the total number of visits to the site at the end of 2017 was more than 230.000.

The two-year impact factor of RISC, according to data for 2017, was 0.439, taking into account citation from all sources - 0.570, and the five-year impact factor of RISC - 0.352.

Medical Radiology and Radiation Safety. 2023. Vol. 68. № 6

DOI:10.33266/1024-6177-2023-68-6-106-117

N.V. Denisova1, 2, A.V. Nesterova1, 2, S.M. Minin3, Zh.Zh. Anashbayev3,
S.E. Krasilnikov3, W.Yu. Ussov3

Development of Software Tools Based on Clinical Data and Phantom Studies for Mathematical Simulation Modeling to Assess Brain Perfusion and Improve Image Quality During SPECT/CT with 99mTc-GMPAO

1 National Research Novosibirsk State University, Novosibirsk, Russia

2 S.A. Khristianovich Institute of Theoretical and Applied Mechanics, Novosibirsk, Russia

3 Akademian E.N. Meshalkin NMRC, Novosibirsk, Russia

Contact person: Natalia Vasilyevna Denisova, e-mail: This email address is being protected from spambots. You need JavaScript enabled to view it.

 

Abstract

Purpose: To develop a software package Virtual examination of brain perfusion by the method of SPECT/CT with 99mTc-HMPAO (Teoxime) and its practical application to study the conditions for achieving the best image quality in clinical studies of patients.

Material and methods: The studies were performed using clinical data and the method of computer simulation. Clinical data of single-photon emission computed tomography combined with X-ray computed tomography (SPECT/CT) with 99mTc-hexamethylpropyleneamine oxime (99mTc-Teoxime, produced by DIAMED LLC) of a patient with an ischemic stroke of the right frontal cortex were obtained on a two-detector gamma-camera NM/CT 670 DR GE Discovery (USA) using high-resolution low-energy collimators (LEHR). The measured data were processed using specialized software Q.Brain and Q.Volumetrix MI on a Xeleris 4.0 DR workstation from GE Healthcare (USA) to obtain reconstructed axial tomographic slices. To carry out simulation computer simulation of the procedure of examination of perfusion of GM by the method of SPECT/CT has developed a software package that includes a mathematical Hoffman phantom with the ability to simulate clinical cases of hypoperfusion of different localization and size (Virtual Patient), modeling the collection of “raw” projection data and an image reconstruction program based on the OSEM algorithm (Ordered Subset Expectation Maximization). An important advantage of the mathematical modeling method is the ability to assess the quality of the reconstructed image by calculating the root-mean-square error when compared with a given phantom. In numerical experiments, the dependence of the reconstruction error on the parameters of the OSEM algorithm (on the number of subgroups – subsets, and on the number of iterations) was investigated in order to determine the conditions for achieving the best image quality. A statistical stop criterion was developed and tested.

Results: For the first time, a software package was developed and tested that allows us to investigate errors in the reconstruction algorithm, which is a great difficulty when using clinical research methods. A criterion for stopping iterations is proposed when using the OSEM reconstruction algorithm – minimizing the functional deviation of the chi-square function from the target value, while the detector pixels with non-zero values are combined into blocks according to the 2×2 scheme.

There is a reliable good correlation between the proposed stop criterion and the minimum of the root-mean-square error of image reconstruction. This makes it possible to introduce this criterion into the clinical practice of using computational tools for reconstructing sections of the SPECT to obtain the best image.

The simulation results demonstrated the possibility of reducing the time of data recording, during which the patient must remain motionless, at least twice.

Conclusion: The method of computer simulation developed in this work is a practically useful technology that helps optimize the use of SPECT to achieve the best possible results of brain imaging in patients.

Keywords: brain perfusion, SPECT/CT, computer modeling, Hoffman’s phantom, iterative reconstruction algorithm

For citation: Denisova NV, Nesterova AV, Minin SM, Anashbayev ZhZh, Krasilnikov SE, Ussov WYu. Development of Software Tools Based on Clinical Data and Phantom Studies for Mathematical Simulation Modeling to Assess Brain Perfusion and Improve Image Quality During SPECT/CT with 99mTc-GMPAO. Medical Radiology and Radiation Safety. 2023;68(6):106–117. (In Russian). DOI:10.33266/1024-6177-2023-68-6-106-117

 

References

1.Juni J.E., Waxman A.D., Devous M.D., Tikofsky R.S., Ichise M., Van Heertum R.L., Carretta R.F., Chen C.C. Society for Nuclear Medicine Procedure Guideline for Brain Perfusion SPECT Using 99mTc Radiopharmaceuticals 3.0. J. Nucl. Med. Technol. 2009;37;3:191-195.

2.Kapucu O.L., Nobili F., Varrone A., Booij J., Vander Borght T., Någren K., Darcourt J., Tatsch K., Van Laere K.J. EANM Procedure Guideline for Brain Perfusion SPECT Using 99mTc-Labelled Radiopharmaceuticals, Version 2. Eur. J. Nucl. Med. Mol. Imaging. 2009;36;12:2093-2102. doi: 10.1007/s00259-009-1266-y.

3.Abadi E., Segars W.P., Tsui B.M.W., Kinahan P.E., Bottenus N., Frangi A.F., Maidment A., Lo J., Samei E. Virtual Clinical Trials in Medical Imaging: a Review. J. Med. Imaging. (Bellingham). 2020;7;4:042805. doi: 10.1117/1.JMI.7.4.042805. 

4.Hoffman 3D Brain Phantom Model BR/3D/P, DATA SPECTRUM Corporation, USA.

5.Shepp L.A., Vardi Y. Maximum Likelihood Reconstruction for Emission Tomography. IEEE Trans. Med. Imaging. 1982;1;2:113–122. doi: 10.1109/TMI.1982.4307558.

6.Veklerov E., Llacer J. Stopping Rule for the MLE Algorithm Based on Statistical Hypothesis Testing. IEEE Trans Med Imaging. 1987;6;4:313-319. doi: 10.1109/TMI.1987.4307849.

7.Nesterova A.V., Denisova N.V. Pitfalls on the Way to Quantify the Severity of Oncological Lesions in Diagnostic Nuclear Medicine. Zhurnal Tekhnicheskoy Fiziki = Journal of Applied Physics. 2022;92;7:1018–1021. DOI: 10.21883/JTF.2022.07.52659.331-21 (In Russ.).

8.Denisova N.V., Terekhov I.N. Computer Simulation of Patient Examination Procedure by the Cardiac SPECT/CT Method. Meditsinskaya Fizika = Medical Physics. 2016;3:87-100 (In Russ.). 

9.Dolya O.P., Klepov A.N., Kurachenko Yu.A., Matusevich E.S. Monte Carlo Simulation of the Sensitivity Function of a Gamma Camera Collimator to Gamma Radiation of an Osteotropic Radiopharmaceutical. Meditsinskaya Fizika = Medical Physics. 2008;2:63-75 (In Russ.). 

10.Kostylev V.A., Kalashnikov S.D., Fishman L.Ya. Emissionnaya Gamma-Topografiya = Emission Gamma Topography. Moscow, Energoatomizdat Publ., 1988. 327 p. (In Russ.).

11.Kostylev V.A. On the Development and Implementation of Medical Nuclear Physics Technologies in Russia. Meditsinskaya Fizika = Medical Physics. 2007;2:5-17 (In Russ.). 

12.Narkevich B.Ya., Krylov A.S., Ryzhkov A.D., Geliashvili T.M. Dosimetric Support of Radionuclide Therapy. Onkologicheskiy Zhurnal: Luchevaya Diagnostika, Luchevaya Terapiya = Journal of Oncology: Diagnostic Radiology and Radiotherapy. 2023;6;1:66-84. DOI: 10.37174/2587-7593-2023-6-1-66-84 (In Russ.).

13.Lee W.W., K-SPECT Group. Clinical Applications of Technetium-99m Quantitative Single-Photon Emission Computed Tomography/Computed Tomography. Nucl. Med. Mol. Imaging. 2019;53;3:172-181. doi: 10.1007/s13139-019-00588-9.

14.Képes Z., Mikó M., Kukuts K., Esze R., Barna S., Somodi S., Káplár M., Varga J., Garai I. Imaging with [99mTc]HMPAO - a Novel Perspective: Investigation of [99mTc]HMPAO Leg Muscle Uptake in Metabolic Diseases. Acta Radiol. 2023;64;1:187-194. doi: 10.1177/028418512110636019.

 

 

 PDF (RUS) Full-text article (in Russian)

 

Conflict of interest. The authors declare no conflict of interest.

Financing. The study had no sponsorship.

Contribution. Denisova N.V. ‒ development of the concept and planning of scientific work, drafting of the manuscript, final approval of the published version of the manuscript; Nesterova AV ‒ mathematical modeling and presentation of its results, participation in the writing and editing of the manuscript; Minin S.M. ‒ analysis of scientific work, critical revision with the introduction of valuable intellectual content; Anashbayev Zh Zh ‒ analysis of scientific work, critical revision with the input of valuable intellectual content, participation in the writing and editing of the manuscript; Krasilnikov S.E. ‒ analysis of scientific work, critical revision and revision with the introduction of valuable intellectual content; Ussov WYu ‒ analysis of primary SPECT data and results of mathematical modeling, graphical representation of results, discussion, participation in writing and editing the manuscript, final approval of the published version of the manuscript.

Article received: 20.07.2023. Accepted for publication: 27.08.2023.

 

Contact Information

 

46, Zhivopisnaya st., 123098, Moscow, Russia Phone: +7 (499) 190-95-51. E-mail: This email address is being protected from spambots. You need JavaScript enabled to view it.

Journal location

Attendance

2765856
Today
Yesterday
This week
Last week
This month
Last month
For all time
1750
4471
24240
18409
73599
75709
2765856

Forecast today
2880


Your IP:216.73.216.222